张怡然1,2, 裴瑞祥1,2, 马娇1,2, 陈卓然1,2, 张剑锋1,2, 王国锋1,2,*   

  1. 1.天津泰达水业有限公司 天津 300457;
    2.天津泰达津联自来水有限公司 天津 300457
  • 收稿日期:2025-06-04 出版日期:2025-07-25 发布日期:2026-01-06
  • 通讯作者: *

Experimental research on influence of different dosage combinations on treatment effect of raw water in water treatment plant

ZHANG Yiran1,2, PEI Ruixiang1,2, MA Jiao1,2, CHEN Zhuoran1,2, ZHANG Jianfeng1,2, WANG Guofeng1,2,*   

  1. 1. Tianjin TEDA Water Industry Co.,Ltd.,Tianjin 300457,China;
    2. Tianjin TEDA Tsinlien Water Supply Co.,Ltd.,Tianjin 300457,China
  • Received:2025-06-04 Online:2025-07-25 Published:2026-01-06

摘要: 以滦河水为原水,进行不同药剂投加组合的中试优化运行研究,通过对不同预氧化投加量、药剂组合投加量下的原水处理效果进行分析,提出不同水质期滦河原水的药剂投加优化参数。在低温低浊期,没有预处理的情况下,聚氯化铝投加20 mg/L,三氯化铁投加15 mg/L;预臭氧0.8 mg/L条件下,聚氯化铝投加10 mg/L,三氯化铁投加10 mg/L,均可满足出水水质要求。在常温常浊期,预加氯0.5 mg/L条件下,聚氯化铝投加15 mg/L,三氯化铁投加15 mg/L,可以满足出水水质要求。在高温高藻期,预加氯1.2 mg/L条件下,聚氯化铝投加20 mg/L,三氯化铁投加15 mg/L,可以满足出水水质要求。

关键词: 原水预氧化, 铁铝复配投加, 中试实验, 优化运行

Abstract: A pilot study was conducted to optimize the operation of different combinations of chemical agents using the Luan River raw water. By analyzing the treatment effects under different pre-oxidation and chemical combination dosages,the optimization parameters of chemical agents for Luan River raw water in different water quality periods were proposed. The results show that during the low-temperature and low turbidity phase of the pilot test,a dosage of 20 mg/L PAC and 15 mg/L FeCl3 without pre-treatment,and a dosage of 0.8 mg/L preozonation,10 mg/L PAC and 10 mg/L FeCl3 can both meet the effluent quality requirements. During the normal temperature and turbidity period,a dosage of 0.5 mg/L prechlorination,15 mg/L PAC and 15 mg/L FeCl3 can meet the effluent quality requirements,and during the high temperature and high algae period,a dosage of 1.2 mg/L prechlorination,20 mg/L PAC and 15 mg/L FeCl3 can meet the effluent quality requirements.

Key words: preoxidation of raw water, iron aluminum compound addition, pilot study, optimization operation